{"id":18934,"date":"2022-08-10T12:27:00","date_gmt":"2022-08-10T09:27:00","guid":{"rendered":"https:\/\/www.ug.medicareexel.net\/index.php\/product\/draeger-anaesthesia-machine\/"},"modified":"2022-10-08T13:19:28","modified_gmt":"2022-10-08T10:19:28","slug":"draeger-anaesthesia-machine","status":"publish","type":"product","link":"https:\/\/www.ug.medicareexel.net\/index.php\/product\/draeger-anaesthesia-machine\/","title":{"rendered":"DRAEGER Primus Anesthesia Machine"},"content":{"rendered":"<p><strong>Technical Data<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td>Gas flow control<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>115 kg (without vaporizers or cylinders)<\/td>\n<\/tr>\n<tr>\n<td>Dimensions (H x W x D)<\/td>\n<td>137 cm x 80 cm x 80 cm<\/td>\n<\/tr>\n<tr>\n<td>Power<\/td>\n<td>200 W, typical<\/td>\n<\/tr>\n<tr>\n<td>Operating voltage<\/td>\n<td>100-240 V<strong>~, <\/strong>45-65 Hz<\/td>\n<\/tr>\n<tr>\n<td>Integrated power backup<\/td>\n<td>at least 30 minutes, typical 90 minutes, depending on ventilation mode<\/td>\n<\/tr>\n<tr>\n<td>Ventilator E-Vent\u00ae plus<\/td>\n<td>Electrically driven and electronically controlled<\/td>\n<\/tr>\n<tr>\n<td>Operating Modes<\/td>\n<td>Manual, spontaneous, Volume Mode (IPPV), Pressure Mode <strong>(PCV),<\/strong><br \/>\nOptional: Pressure Support (PS), Synchronized volume controlled ventilation (SIMV), optional with PS, Synchronized pressure controlled ventilation, optional with PS<\/td>\n<\/tr>\n<tr>\n<td>Pressure limitation PMAx(in Volume Mode)<\/td>\n<td>(PEEP 10) up to 70 hPa<\/td>\n<\/tr>\n<tr>\n<td>Pressure limitation P&#8221;SP (in Pressure Mode)<\/td>\n<td>(PEEP 5) up to 70 hPa<\/td>\n<\/tr>\n<tr>\n<td>Trigger<\/td>\n<td>0.3-15 l\/min<\/td>\n<\/tr>\n<tr>\n<td>Tidal volume (in Volume Mode)<\/td>\n<td>20-1400 ml<br \/>\n5-1400 ml (option)<\/td>\n<\/tr>\n<tr>\n<td>Tidal volume (in Pressure Mode)<\/td>\n<td>10-1400 ml<\/td>\n<\/tr>\n<tr>\n<td>Breathing frequency (freq.)<\/td>\n<td>3-80 1\/min<\/td>\n<\/tr>\n<tr>\n<td>Inspiration time [T(INSP)]<\/td>\n<td>0.2-6.7 s<\/td>\n<\/tr>\n<tr>\n<td>Inspiration\/Expiration time ratio (l:E)<\/td>\n<td>max. 5:1 to 1:99<\/td>\n<\/tr>\n<tr>\n<td>Plateau time [T(IP):T(INSP)]<\/td>\n<td>0-60 %<\/td>\n<\/tr>\n<tr>\n<td>PEEP in Volume Mode<\/td>\n<td>0-20 hPa (max. PMAx -10 hPa)<\/td>\n<\/tr>\n<tr>\n<td>PEEP in Pressure Mode<\/td>\n<td>0-20 hPa (max. P,NSP -5 hPa)<\/td>\n<\/tr>\n<tr>\n<td>Fresh-gas flow<\/td>\n<td>0 and 0.2-18 Umin<\/td>\n<\/tr>\n<tr>\n<td>T (SLOPE) (in Pressure Mode and Pressure Support)<\/td>\n<td>0-2 s<\/td>\n<\/tr>\n<tr>\n<td>Total system leakage<\/td>\n<td>&lt; 150 ml at 30 hPa (automatic leak test)<\/td>\n<\/tr>\n<tr>\n<td>O2 flow control<\/td>\n<td>Sensitive ORC function: at least 25 Vol.% or 200 ml\/min for nitrous oxide (N20) as carrier gas; 02 concentration: 21-100 Vol.%<\/td>\n<\/tr>\n<tr>\n<td>O2 flush<\/td>\n<td>&gt; 35 Umin<\/td>\n<\/tr>\n<tr>\n<td>02 safety flow<\/td>\n<td>0-12 l\/min<\/td>\n<\/tr>\n<tr>\n<td>External fresh gas outlet<\/td>\n<td>optional<\/td>\n<\/tr>\n<tr>\n<td>Monitoring<\/td>\n<td>lnspiratory and expiratory concentration of 02, N20, CO2 as well as anaesthetic agents (Halothane, lsoflurane, Sevoflurane, Desflurane); Minute volume (MV) and Tidal volume (VT); Breathing frequency; Peak pressure, plateau pressure, mean pressure, PEEP; Patient compliance CPAT; Option: Functional oxygen saturation (SpO2)<\/p>\n<p>The following parameters maybe displayed as waveforms: Concentration of CO2, O2, as well as anaesthetic agents, airway pressure, inspiratory and expiratory flow; Option: Plethysmogram; Bar graph display of volumeter and tidal volume; Virtual flow tubes or O2, AIR, N2O; Display of graphical trends and numerical lists of measured values; AutoSet for alarm limits<\/td>\n<\/tr>\n<tr>\n<td>Serial interface<\/td>\n<td>3 x RS 232<\/td>\n<\/tr>\n<tr>\n<td>Protocol<\/td>\n<td>Medibus<\/td>\n<\/tr>\n<tr>\n<td>Absorber volume<\/td>\n<td>1.5 L<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Technical Data Gas flow control Weight 115 kg (without vaporizers or cylinders) Dimensions (H x W x D) 137 cm x 80 cm x 80 cm Power 200 W, typical Operating voltage 100-240 V~, 45-65 Hz Integrated power backup at least 30 minutes, typical 90 minutes, depending on ventilation mode Ventilator E-Vent\u00ae plus Electrically driven [&hellip;]<\/p>\n","protected":false},"featured_media":18935,"template":"","meta":[],"product_cat":[332],"product_tag":[329],"class_list":["post-18934","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-anesthesia-machines","product_tag-refurbished","pa_condition-refurbished","ts_product_brand-draeger"],"_links":{"self":[{"href":"https:\/\/www.ug.medicareexel.net\/index.php\/wp-json\/wp\/v2\/product\/18934","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ug.medicareexel.net\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.ug.medicareexel.net\/index.php\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ug.medicareexel.net\/index.php\/wp-json\/wp\/v2\/media\/18935"}],"wp:attachment":[{"href":"https:\/\/www.ug.medicareexel.net\/index.php\/wp-json\/wp\/v2\/media?parent=18934"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.ug.medicareexel.net\/index.php\/wp-json\/wp\/v2\/product_cat?post=18934"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.ug.medicareexel.net\/index.php\/wp-json\/wp\/v2\/product_tag?post=18934"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}