{"id":19105,"date":"2022-09-21T18:21:26","date_gmt":"2022-09-21T15:21:26","guid":{"rendered":"https:\/\/www.ug.medicareexel.net\/index.php\/product\/fresenius-vial-syringe-pump\/"},"modified":"2022-10-08T13:21:30","modified_gmt":"2022-10-08T10:21:30","slug":"fresenius-vial-syringe-pump","status":"publish","type":"product","link":"https:\/\/www.ug.medicareexel.net\/index.php\/product\/fresenius-vial-syringe-pump\/","title":{"rendered":"FRESENIUS Vial Orchestra Module DPS Syringe Pump"},"content":{"rendered":"<h3><strong>Performance:<\/strong><\/h3>\n<table style=\"height: 801px;\" width=\"1166\">\n<tbody>\n<tr>\n<td>FLOW RATE RANGE<\/td>\n<td>From 0,1 to\u00a0 1200 ml\/h, in 0,1 ml\/h increments.<\/td>\n<\/tr>\n<tr>\n<td>ACCURACY<\/td>\n<td>\u00b1 1 % on mechanism\u00a0 (measured-time: &gt; 1 hour, minimum 1 ml).<\/td>\n<\/tr>\n<tr>\n<td>SYRINGE CAPACITIES<\/td>\n<td>5, 10, 20, 30\/35, 50\/60 mI.<\/td>\n<\/tr>\n<tr>\n<td>TWO OCCLUSION\u00a0 PROGRAMMING MODES PRESSURE\u00a0 ALARM\u00a0 LEVELS<\/td>\n<td>Variable threshold mode: numerically\u00a0 selected occlusion pressure\u00a0 alarm. Pre-selection mode: 3 pre-selected\u00a0 occlusion levels.<\/td>\n<\/tr>\n<tr>\n<td>OCCLUSION\u00a0 PRE-ALARM<\/td>\n<td>Imminent\u00a0 occlusion warning.<\/td>\n<\/tr>\n<tr>\n<td>DPS &#8211; DYNAMIC\u00a0 PRESSURE SYSTEM<\/td>\n<td>Line disconnection\u00a0 alarm, indication of pressure increase and decrease in the\u00a0 infusion line, increase pressure\u00a0 alarm.<\/td>\n<\/tr>\n<tr>\n<td>DOUBLE PRESSURE\u00a0 DISPLAY<\/td>\n<td>Numerical values of the line pressure\u00a0 and the selected limit, graphic representation of the\u00a0 pressure in the infusion line and of the pressure limit.<\/td>\n<\/tr>\n<tr>\n<td>VOLUME\u00a0 LIMIT<\/td>\n<td>From 0,1 to\u00a0 999,9 ml in 0,1 ml\u00a0 increments.<\/td>\n<\/tr>\n<tr>\n<td>BOLUS RATE<\/td>\n<td>From 50\u00a0 ml\/h to 1200 ml\/h, programmable.<\/td>\n<\/tr>\n<tr>\n<td>INDUCTION\u00a0 PROGRAMMING<\/td>\n<td>Rate: from 0,1 to\u00a0 1200 ml\/h, volume: from 0,1 ml\u00a0 to\u00a0 120 ml.<\/td>\n<\/tr>\n<tr>\n<td>ANTI-BOLUS SYSTEM<\/td>\n<td>Reduces significantly bolus after occlusion release (0,2 ml max).<\/td>\n<\/tr>\n<tr>\n<td>MAINTENANCE<\/td>\n<td>Preventive maintenance\u00a0 warning based on the\u00a0 customers downloading.<\/td>\n<\/tr>\n<tr>\n<td>HISTORICAL<\/td>\n<td>Event login.<\/td>\n<\/tr>\n<tr>\n<td>DRUG NAMES<\/td>\n<td>15 drug names programmable\u00a0 by configuration.<\/td>\n<\/tr>\n<tr>\n<td>ALARMSANDPREALARMS<\/td>\n<td>Syringe position control: syringe barrel clasp check, plunger head detection, anti-siphon system check, locking handle.<br \/>\nInfusion control: occlusion\u00a0 pressure prealarm, occlusion pressure\u00a0 alarm, end of infusion prealarm, end of infusion alarm, volume limit\u00a0 prealarm, volume limit\u00a0 alarm, KVO rate.<br \/>\nDevice control: disengaged\u00a0 driving mechanism alarm, low battery prealarm, discharged\u00a0 battery alarm, battery capacity display in hours and minutes, unconfirmed\u00a0 programming, technical\u00a0 malfunction\u00a0 alarm (auto-test, rotation), drive system advance check, watchdog check, RS232 interface failure, unlocked<br \/>\nModule.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>Technical Specifications:<\/strong><\/h3>\n<table style=\"height: 227px;\" width=\"973\">\n<tbody>\n<tr>\n<td>DIMENSIONS\/\u00a0 WEIGHT<\/td>\n<td>H 10,5 x W 31,5 x D 13,5 cm \/ &#8211;\u00a0 2,3 kg.<\/td>\n<\/tr>\n<tr>\n<td>EXTERNAL SUPPLY<\/td>\n<td>7,15 Vdc (with the Base or the Mainy Mod).<\/td>\n<\/tr>\n<tr>\n<td>BATTERY\/ BATTERY\u00a0 LIFE<\/td>\n<td>Lead acid battery\u00a0 &#8211; 6 V 1.1 to\u00a0 1.3 Ah\/\u00a0\u00a0 7 hours minimum at 5 ml\/h.<br \/>\nDisplay of real battery life in hours and minutes.<\/td>\n<\/tr>\n<tr>\n<td>COMPLIANCE, STANDARDS<\/td>\n<td>Complies with EN 60601-1, EN 60601-1-2 and EN 60601-2-24.<br \/>\nCE 0459 Marking in compliance\u00a0 with the EEC 93\/42 European Medical Device Directive.<\/td>\n<\/tr>\n<tr>\n<td>WATERPROOFNESS<\/td>\n<td>Protection against splashing liquid: IP 34.<\/td>\n<\/tr>\n<tr>\n<td>ELECTRICAL\u00a0 COMPLIANCE<\/td>\n<td>Protection against leakage current: CF type. Protection against electric shocks: class II.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Performance: FLOW RATE RANGE From 0,1 to\u00a0 1200 ml\/h, in 0,1 ml\/h increments. ACCURACY \u00b1 1 % on mechanism\u00a0 (measured-time: &gt; 1 hour, minimum 1 ml). SYRINGE CAPACITIES 5, 10, 20, 30\/35, 50\/60 mI. TWO OCCLUSION\u00a0 PROGRAMMING MODES PRESSURE\u00a0 ALARM\u00a0 LEVELS Variable threshold mode: numerically\u00a0 selected occlusion pressure\u00a0 alarm. Pre-selection mode: 3 pre-selected\u00a0 occlusion levels. [&hellip;]<\/p>\n","protected":false},"featured_media":19106,"template":"","meta":[],"product_cat":[367],"product_tag":[329],"class_list":["post-19105","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-syringe-pumps","product_tag-refurbished","pa_condition-refurbished","ts_product_brand-fresenius"],"_links":{"self":[{"href":"https:\/\/www.ug.medicareexel.net\/index.php\/wp-json\/wp\/v2\/product\/19105","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ug.medicareexel.net\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.ug.medicareexel.net\/index.php\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ug.medicareexel.net\/index.php\/wp-json\/wp\/v2\/media\/19106"}],"wp:attachment":[{"href":"https:\/\/www.ug.medicareexel.net\/index.php\/wp-json\/wp\/v2\/media?parent=19105"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.ug.medicareexel.net\/index.php\/wp-json\/wp\/v2\/product_cat?post=19105"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.ug.medicareexel.net\/index.php\/wp-json\/wp\/v2\/product_tag?post=19105"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}